Do you have questions about an electromagnetic audit, its price, what it measures or what science says? Here are the answers to the most frequent questions. If yours is not here, contact us: the first phone conversation is free.

Understanding the audit

What does an electromagnetic audit at home involve?

An on-site visit, with measurement of electric fields, magnetic fields and radio frequencies (antennas, Wi-Fi, DECT, meters), a check of the earthing and a search for dirty electricity. After the measurements, improvement solutions are tested on site. A detailed written report, with mitigation options ranked by priority, is sent after the audit.

On request and at no extra cost, the audit can be completed with a measurement of radon and air quality.

What exactly do you measure: radio frequencies, low frequencies, dirty electricity?

Three families: radio frequencies (mobile masts, Wi-Fi, telephony), low-frequency fields (wiring, appliances, power lines) and disturbances on the electrical network (dirty electricity) or earthing faults. To learn more, read the article Dirty electricity.

How does a visit go, and how long does it take?

Before the visit, a short phone call prepares it. The audit takes between 2 and 4 hours depending on needs. The rooms where you spend a lot of time are audited (living room, office, bedrooms). Resting areas, bedrooms in particular, are the most important rooms to clean up from electromagnetic stress.

You always accompany the auditor and take part in the measurements and the solutions. At the start of the audit, you may be asked to switch off the electricity for 15 minutes.

When should I have an audit: pregnancy, sleep problems, buying a property, a new antenna?

Common situations: sleep problems, symptoms linked to certain appliances, an antenna or high-voltage line planned nearby, buying a house or a plot of land, a child's room to be furnished, staff complaints at the office.

Even without any of these reasons, EMesura recommends an audit to better understand the waves present in a home. Several electromagnetically hypersensitive people attribute their symptoms to an excess of waves (DECT phone, very close antenna, Wi-Fi too close…). Even though there is still debate about the level at which waves affect health, enough scientific studies raise the alarm for us to recommend a precautionary principle.

Why take an interest in the electromagnetic environment now?

Our homes concentrate a growing number of sources: the home electrical network and distribution board (low frequencies, 50 Hz), Wi-Fi router, DECT landline phone, connected objects, smart meters, and surrounding 2G/3G/4G/5G mobile masts (high frequencies). These exposures, each weak on its own, add up and are often continuous, including during sleep.

According to Bandara & Carpenter (a commentary published in The Lancet Planetary Health, 2018), the level of radiofrequency radiation around 1 GHz, the main band for wireless communications, would today be about 1018 times higher than its natural level. It would most likely be the human-made environmental exposure that has increased the most since the middle of the 20th century.

Over the last 40 years:

  • The number of sources has exploded: mobile masts, Wi-Fi, DECT, connected objects. In 1980 there was no consumer mobile phone.
  • The nature of the waves has changed: distant, continuous radio and television signals have given way to pulsed digital signals at higher frequencies.
  • Sources have moved closer to the body: a phone carried on you exposes you far more than the general background.

What should I prepare before the visit, and what happens during it?

You are asked to: give access to all the places to be audited (safe access, limited clutter, accessible power sockets); be present throughout the audit; keep animals out of the way; deactivate and mention any alarm systems; mention any special installations (smart meter, home automation, connected devices). If you are a tenant, the owner's or building manager's agreement is needed.

Some measurements require temporarily switching off the electricity or removing the batteries of a cordless phone. Equipment settings (Wi-Fi box, printer…) may be changed on recommendation. EMesura cannot be held liable for indirect consequences (devices resetting, loss of settings, a freezer defrosting, an alarm going off…).

What are the limits of the audit?

The measurements are spot measurements and reflect the conditions at the time of the visit (load on the electrical network, appliances in use, wave propagation conditions). They can vary over time. The audit provides an indicative, educational assessment; it does not replace a regulatory measurement by an accredited body when one is required (for example in a dispute with a telecom operator).

EMesura carries out no medical activity: the audit is neither a medical diagnosis nor a treatment. EMesura is committed to the means it uses (an obligation of means), not to a result, because the actual reduction of exposure also depends on outside factors (third-party sources, network changes, occupants' behaviour).

Prices and practicalities

How much does an electromagnetic audit cost in Belgium?

The first contact by phone (15 minutes) is free. The price of an audit depends on the type of audit (residential, land, professional), the size of the property, the number of rooms to audit and the distance from Fernelmont. The written report is included, as is the radon and air-quality measurement if you want it.

The indicative prices, VAT included, are in the table in the Pricing section of the Our offer page.

In some cases a simplified audit is enough and reduces the cost. Contact EMesura for an opinion; the answer is free.

Which areas do you cover, and what are the travel costs?

Based in Fernelmont, EMesura works in Belgium and the Benelux. Travel costs depend on the distance from Fernelmont. The conditions (free zone, rate per kilometre, work outside the Benelux) are in the table in the Pricing section of the Our offer page.

How do the quote, the deposit and payment work?

Every job starts with a prior quote, free of charge and valid for 30 days. The contract is formed when you accept the quote in writing (signature, e-mail or payment of the deposit). A deposit is requested when you order; the balance is due on receipt of the report. The details are in our General Terms of Sale.

What happens if I cancel or need to postpone the appointment?

A cancellation less than 48 hours before the appointment, or a no-show, results in a compensation fee of €100 plus the travel costs already incurred. If EMesura cannot keep the appointment (illness, equipment failure, weather, force majeure…), it is postponed at no cost or penalty to you.

Is a report provided, and what does it contain?

Yes, a detailed written report is included with every audit. In practice, two reports are sent by e-mail: a summary, with the key points to remember and a possible action plan, and a second report with the detail of the measurements, information on the property's environment and explanations of why an electromagnetic audit is worthwhile.

Can a plot of land be audited before buying or building?

Yes. The land audit takes place before the purchase or before a permit application is filed. Its price is in the table in the Pricing section of the Our offer page. We strongly recommend that all buyers audit their land or house before buying, to know the electromagnetic environment.

Health and standards

Are waves dangerous for health?

In 2011, the International Agency for Research on Cancer (IARC), an agency of the World Health Organization, classified radiofrequency electromagnetic fields as "possibly carcinogenic to humans" (group 2B), as it had done for low-frequency magnetic fields in 2002. This classification reflects scientific uncertainty: it does not establish a demonstrated causal link, but it justifies a precautionary approach, especially in places where people spend long periods, such as bedrooms. To date, there is no definitive scientific consensus on the health effects of chronic low-level exposure.

Some people report non-specific symptoms (sleep problems, fatigue, headaches, irritability, altered touch sensitivity, burning sensations under the skin, dizziness…) that they attribute to exposure to waves (electromagnetic hypersensitivity). Health authorities (WHO, ANSES, the Belgian Superior Health Council) consider that these symptoms are real and must be taken seriously, even though no causal link with electromagnetic exposure has been established so far.

As a precaution, extra attention is often recommended for more sensitive groups (children, pregnant women, elderly or sick people). In Belgium, the Superior Health Council (opinion no. 8081) recommends, as a precaution, limiting children under 15's average exposure to the 50 Hz magnetic field to 0.4 µT (400 nT).

What is the ALARA principle?

The ALARA principle (As Low As Reasonably Achievable) is a radiation-protection principle, later extended to other areas of risk management such as electromagnetic fields.

Rather than setting a single threshold below which "everything is safe" and above which "everything is dangerous", ALARA starts from this idea: when we are not certain that a safe threshold exists (or the threshold is poorly known), we seek to reduce exposure as far as it is reasonable to do so, taking into account:

  • the available technical knowledge (are there means to reduce exposure?),
  • economic factors (is the cost of the reduction proportionate to the expected benefit?),
  • social and practical factors (is the reduction compatible with how the device or activity is used?).

It is therefore not a requirement of zero exposure, but a logic of continuous optimisation, to be applied even when exposure is already below the regulatory limits.

For low-frequency fields, where scientific uncertainty is documented (IARC 2B classification, etc.), agencies such as ANSES recommend ALARA rather than saying "it is dangerous" or "it is harmless": move beds away from electrical panels, do not hold transmitting devices against the body, limit unnecessary exposure. These are common-sense, low-cost measures, applied as a precaution rather than on the basis of proven danger.

What is the difference between legal standards, ICNIRP and precautionary values (SBM-2024)?

ICNIRP values aim to prevent short-term thermal effects; precautionary values such as SBM-2024 are much lower and also target long-term biological effects. There is no debate about whether a limit on exposure to waves is needed: the debate is essentially about which limit value to apply.

Legal standards, national or regional depending on the country (in Belgium they depend on the Regions), essentially govern the emissions of mobile phone masts, measured according to an official protocol. They do not cover most domestic sources (Wi-Fi, DECT, Bluetooth, smart meters, electrical wiring) assessed indoors. For these, the audit relies on indicative precautionary values used in building biology (the SBM-2024 reference framework), which are not a legal standard but a prudent benchmark, especially for sleeping areas.

To go further, read the article Electromagnetics, measured: legal limits, precaution and ALARA.

SAR or power density: which should I look at?

SAR describes the energy absorbed by the body when a device is used; power density describes the ambient exposure at a place. To go further, read the article SAR and power density.

Does electromagnetic hypersensitivity exist, and can anything be measured?

The symptoms described are real for the people concerned. The audit makes it possible to measure the environment and act on what can be measured. To go further, read the articles A real suffering, too long ignored and Real symptoms, a measurable exposure.

To reduce exposure to waves, do we have to avoid new technologies?

No. In fact, EMesura is a fan of new technologies and never refuses to test new products. Improving quality of life at home or at the office is a fundamental issue. The aim is not to slow down modern technology but to use it in the best possible way. Cleaning up an office removes some unnecessary electromagnetic stress and supports dynamic, efficient work. Cleaning up a home increases well-being and reduces unnecessary exposure, as a precaution.

Trust and independence

Are you independent? Do you sell protective products?

Nothing is sold before the audit, and no sale is tied to booking an audit. Advice starts with measurement. After the audit, if the measurements show that a product can bring an improvement, EMesura may offer you certain products (shielding or attenuation materials, filters, cabling…). We only recommend materials and equipment that we have measured.

There is no obligation to buy equipment through EMesura: you remain free to go elsewhere or to buy nothing.

Are my data, my photos and the report protected?

EMesura undertakes to keep confidential all the information gathered during the assignment (personal data, layout of the premises, the client's activity). Data is processed in accordance with the GDPR and kept for 5 years; you can request access, rectification or erasure at bernard.monville@emesura.com. Some measurements may be used anonymously for statistical studies, never without your agreement if they could identify the home.

Photographs taken during the audit are used only to prepare your report. Any other use (communication, social media…) requires your express, prior consent.

The report is intended for your personal use or that of your company; passing it to a third party (insurer, landlord, notary…) requires your agreement, and you bear the consequences. It has the value of technical guidance: it is a measurement at a given moment, without systematic evidential value in court, and it is not aimed at anyone (neighbour, operator…).

What equipment and reference frameworks do you use?

Equipment: Gigahertz, Safe and Sound, Green Wave, Tohm-e Solutions, Cemprotec, RFExplorer, Siretta, AlphaLab, RadonEye. Reference frameworks: ICNIRP, SBM-2024, BioInitiative, EUROPAEM. The advice is based on the Building Biology Guidelines, commonly used by electromagnetic-environment advisers.

Who is Bernard Monville?

A civil electromechanical engineer, with 33 years in industry and 8 years in the field of electromagnetic waves. EMesura SRL, Fernelmont, company no. BCE 1041.846.019.